Go to main content

Search Welders Net

Welding Amperage and Settings Calculator

By First published

Choose a process, a metal and its thickness. The calculator returns a starting amperage, the wire, electrode or tungsten size and the shielding gas flow, each tied to a Lincoln, Miller or similar manufacturer document. Every range is a starting point: follow your machine's manual. Values marked Unconfirmed couldn't be checked against the maker's current documentation, and anything we could not source says "unconfirmed".

Amperage and settings calculator

Results update as you change a field and are saved in the page address. Nothing leaves your browser. All numbers are starting points; follow your machine's manual.

Process, metal and thickness

Miller's gauge table: 18 ga = 0.047 in., 16 = 0.062, 14 = 0.078, 12 = 0.100, 10 = 0.125, 8 = 0.156, 6 = 0.187.

Starting settings

How the settings are worked out

MIG starts from Miller's welder's rule of thumb, then matches a wire whose published amp range holds that number and converts amps to wire feed speed with Miller's burn-off rates. Stick looks up Lincoln's published current for the electrode and diameter you choose. TIG picks the smallest tungsten whose Miller range covers the amps. Gas flow is the figure printed in the Miller or Lincoln document named in the result.

MIG and TIG starting amps; MIG wire feed
starting amps    = thickness (in.) × 1000 × 1 A per 0.001 in.
wire feed speed  = amps × burn-off (in. of wire per amp per minute)
wire             = the size whose published amp range holds the amps, nearest the middle
burn-off
3.5 (0.023 in.), 2 (0.030), 1.6 (0.035), 1 (0.045) per Miller
TIG
the same rule is used as a starting estimate and is marked unconfirmed for TIG

Worked example

Given: MIG, mild steel, solid wire; 1/8 in. (0.125 in.) thick.

  1. Starting amps: 0.125 × 1000 × 1 = 125 A Unconfirmed: check your machine's manual
  2. Wire: 0.035 in. is published at 80-175 A (Lincoln), and 125 A is inside it: 0.035 in. ER70S-6 Unconfirmed: check your machine's manual
  3. Wire feed speed: 125 × 1.6 = 200 in./min Unconfirmed: check your machine's manual
  4. Gas, 75/25 Ar/CO2: Lincoln 15-20 CFH, Miller 25 CFH Unconfirmed: check your machine's manual

Answer: About 125 A with 0.035 in. wire at about 200 in./min. This matches Miller's worked example for 1/8 in. steel. Voltage comes from your machine's chart.

Unconfirmed values. This result uses values we couldn't verify against the maker's current documentation. Treat it as a starting point and follow your equipment manual.

Stick electrode current (Lincoln)

Lincoln typical operating current by diameter
Electrode and diameterDC (see note)AC
E6010 3/32 in. 50-85 A Unconfirmed: check your machine's manualnot listed
E6010 1/8 in. 75-135 A Unconfirmed: check your machine's manualnot listed
E6010 5/32 in. 100-175 A Unconfirmed: check your machine's manualnot listed
E6011 3/32 in. 40-80 A Unconfirmed: check your machine's manual40-90 A Unconfirmed: check your machine's manual
E6011 1/8 in. 60-110 A Unconfirmed: check your machine's manual65-120 A Unconfirmed: check your machine's manual
E6011 5/32 in. 105-135 A Unconfirmed: check your machine's manual115-150 A Unconfirmed: check your machine's manual
E6013 3/32 in. 70-105 A Unconfirmed: check your machine's manual75-115 A Unconfirmed: check your machine's manual
E6013 1/8 in. 100-135 A Unconfirmed: check your machine's manual110-140 A Unconfirmed: check your machine's manual
E7018 3/32 in. 70-110 A Unconfirmed: check your machine's manual80-120 A Unconfirmed: check your machine's manual
E7018 1/8 in. 90-160 A Unconfirmed: check your machine's manual100-160 A Unconfirmed: check your machine's manual
E7018 5/32 in. 130-210 A Unconfirmed: check your machine's manual140-210 A Unconfirmed: check your machine's manual

Source 3. E6010 is DC electrode positive; E7018 is DC electrode positive or AC; E6011 and E6013 pages list AC and DC either polarity. "Not listed" means the row was not legible in what we opened: unconfirmed. Source could not be re-opened on 2026-11-14 for 38 values.

Tungsten electrode current (Miller)

Miller tungsten amperage ranges, argon
Tungsten diameterDC electrode negativeAC with high frequency
1/16 in. 50-160 A Unconfirmed: check your machine's manual50-150 A Unconfirmed: check your machine's manual
3/32 in. 135-235 A Unconfirmed: check your machine's manual135-235 A Unconfirmed: check your machine's manual
1/8 in. 250-400 A Unconfirmed: check your machine's manual225-360 A Unconfirmed: check your machine's manual

Source 4. The 3/32 in. row is the overlap of two Miller editions that disagree on its limits. Larger and smaller sizes exist; we did not carry their rows. Source could not be re-opened on 2026-11-14 for 12 values.

Assumptions and limits

  • Every range is a starting point; follow your machine's manual. Voltage, travel speed and technique are not included.
  • MIG settings cover mild steel with solid ER70S-6 wire. Stainless and aluminum MIG are unconfirmed here: the calculator says so rather than guess.
  • The 1 A per 0.001 in. rule is printed in Miller's MIG guide. We use it as a TIG and flux-core starting estimate too, and mark those rows unconfirmed, because we did not open a Miller or Lincoln page that states it for those processes.
  • Flux-core wire amp ranges and electrode choice by thickness for stick are unconfirmed. The stick result shows Lincoln's published current for the rod you pick, and checks it against Miller's 18 gauge floor (source 9).
  • Self-shielded flux-core: Lincoln's chart footnote says .035 and .045 in. NR-211-MP are recommended only up to 5/16 in. on that chart. Check your wire's data sheet.
  • Values marked Unconfirmed couldn't be checked against the maker's current documentation; follow your machine's manual. 80 of the 80 dataset values behind this page are in that state, so each result and table says so. Manufacturer documents change, and Miller's source PDFs sometimes move, so a link may need a search for the title.

Questions we get

How many amps do I need to weld 1/8 inch steel?

Miller's welder's rule of thumb is about 1 amp per 0.001 inch of thickness, so 1/8 inch (0.125 in.) is about 125 A. That is a MIG starting point. For 0.035 in. solid wire, Lincoln publishes 80-175 A, and 125 A sits inside it. Fine-tune for joint, position, gas and your technique.

What wire size should I use for MIG?

Pick the wire whose published amperage range holds your starting amps, ideally near its middle (Miller's guidance). Lincoln lists 80-175 A for 0.035 in. and 145-200 A for 0.045 in. For amps below that, thinner wire such as 0.023 or 0.030 in. is used, but we did not open a published amp range for them, so the calculator marks that as unconfirmed.

How do I find wire feed speed from amps?

Multiply amps by the wire's burn-off rate. Miller lists 3.5, 2, 1.6 and 1 inches of wire per amp per minute for 0.023, 0.030, 0.035 and 0.045 in. wire. At 125 A with 0.035 in. wire that is 200 inches per minute, which is Miller's own example.

How much shielding gas flow do I need?

For solid steel wire with 75% argon and 25% CO2, Miller's manual shows 25 CFH and Lincoln's shows 15-20 CFH, or 20-25 CFH out of position or in a draft. For TIG, Miller gives typical argon flow of 15-35 CFH. Gas-shielded flux-core runs higher: 40-50 CFH in Lincoln's data sheet.

What amperage should I run for 7018 rods?

Lincoln's Excalibur 7018 MR page lists 70-110 A for 3/32 in., 90-160 A for 1/8 in. and 130-210 A for 5/32 in. on DC electrode positive, with slightly different AC ranges. Use the lower part for vertical and overhead work and for thinner metal, and your electrode's own data sheet for other brands.

Why does the calculator say "unconfirmed"?

Safety-critical settings should come from a manufacturer document we opened, with a date. Where we could not open one, the tool says so instead of guessing. Aluminum and stainless MIG settings, flux-core wire amp ranges and the TIG amps-per-thickness rule fall in that group. Use your machine's chart for those. Separately, values marked Unconfirmed in the results and tables could not be checked against the maker's current documentation; follow your machine's manual.

Are these settings a procedure?

No. They are starting points for practice on scrap. Structural, pressure and other code work follows a qualified welding procedure, not a calculator.

Where we got this

  1. Miller Electric, MIG welding instructor guide: 1 A per 0.001 in. rule of thumb, wire burn-off (in./amp) and Table 2 gauge-to-thickness (millerwelds.com) Source could not be re-opened on 2026-11-14 for 12 values.
  2. Lincoln Electric, SuperArc L-56 (ER70S-6) data sheet C110: 0.035 and 0.045 in. wire amp ranges (lincolnelectric.com) Source could not be re-opened on 2026-11-14 for 4 values. DC+, short-circuit transfer, 100% CO2.
  3. Lincoln Electric, E6010 Fleetweld 5P+, E6011 Fleetweld 180, E6013 Fleetweld 37 and E7018 Excalibur 7018 MR product pages: typical current by diameter (lincolnelectric.com) Source could not be re-opened on 2026-11-14 for 38 values. Other pages: Fleetweld 5P+ https://prodcd.lincolnelectric.com/cs-CZ/Products/fleetweld5pplus_smaw; Fleetweld 180 https://prodcd.lincolnelectric.com/en-SG/Products/fleetweld180_smaw?sku=ED010110; Fleetweld 37 https://prodcd.lincolnelectric.com/fi-FI/Products/fleetweld37_smaw
  4. Miller Electric, TIG owner's manual OM-2233: tungsten diameter amperage ranges and argon flow (millerwelds.com) Source could not be re-opened on 2026-11-14 for 18 values. Miller notes the figures are a composite of AWS and electrode-maker recommendations.
  5. Miller Electric, Millermatic owner's manual OM-230693, Section 4-15: 75% Ar / 25% CO2 at 25 CFH for solid steel wire (millerwelds.com) Source could not be re-opened on 2026-11-14 for 1 value.
  6. Lincoln Electric, POWER MIG operator's manual IM795: 15-20 CFH, 20-25 CFH out of position or drafty (manualzz.com) Source could not be re-opened on 2026-11-14 for 4 values.
  7. Lincoln Electric, Outershield 71 Elite (E71T-1) data sheet C3103: 40-50 CFH with 75-82% argon (lincolnelectric.com) Source could not be re-opened on 2026-11-14 for 2 values.
  8. Lincoln Electric, POWER MIG 215XT manual 11521: Innershield NR-211-MP chart footnote (maximum 5/16 in.), DC- for Innershield, DC+ for Outershield (manualmachine.com) Source could not be re-opened on 2026-11-14 for 1 value.
  9. Miller Electric, "Buying Your First Welder": stick limited to metals no thinner than 18 gauge (millerwelds.com) Accessed 2026-11-14.
  10. OSHA, 29 CFR 1910.252: Welding, cutting, and brazing, general requirements (fire prevention (a), eye protection (b), ventilation (c)) (osha.gov) Accessed 2026-11-14.
  11. NIOSH (CDC), "Welding Fumes and Manganese" (cdc.gov) Accessed 2026-11-14.
  12. NIOSH, Criteria for a Recommended Standard: Welding, Brazing, and Thermal Cutting, Publication 88-110 (cdc.gov) Accessed 2026-11-14.
  13. AWS, ANSI Z49.1 Safety in Welding, Cutting, and Allied Processes (AWS Safety and Health Committee recommends following it and the manufacturer's Safety Data Sheets) (pubs.aws.org) Accessed 2026-11-14. Listing is the 2012 edition; use the current edition from AWS.

Keep reading